Detail
Inline Fluoropolymer Chemical Heat Exchangers
Basic information



Inline Fluoropolymer Chemical Heat Exchangers:

Inline Fluoropolymer Chemical Heat ExchangersInline Fluoropolymer Chemical Heat Exchangers

Inline Fluoropolymer Chemical Heat Exchangers

Fluoropolymer Inline Heat Exchangers

Exchange Area

(Sq.Ft)

Length

In(mm)

DIA

In(mm)

PP Shell

PVDF Shell

6.5

15.7

(400)

10

(255)

XCH6.5-***

XPH6.5-***

13

15.7

(400)

12

(305)

XCH13-***

XPH13-***

20

20

(500)

14

(355)

XCH20-***

XPH20-***

30

20

(500)

14

(355)

XCH30-***

XPH30-***

40

24

(600)

14

(355)

XCH40-***

XPH40-***

50

24

(600)

16

(405)

XCH50-***

XPH50-***

60

27.5

(700)

16

(405)

XCH60-***

XPH60-***

70

27.5

(700)

16

(405)

XCH70-***

XPH70-***

80

31.4

(800)

16

(405)

XCH80-***

XPH80-***

90

31.4

(800)

18

(460)

XCH90-***

XPH90-***

100

31.4

(900)

18

(460)

XCH100-***

XPH100-***

110

31.4

(900)

20

(510)

XCH110-***

XPH110-***

120

39

(1000)

20

(510)

XCH120-***

XPH120-***

130

39

(1000)

20

(510)

XCH130-***

XPH130-***

140

43

(1100)

22

(560)

XCH140-***

XPH140-***

150

43

(1100)

22

(560)

XCH150-***

XPH150-***

160

47

(1200)

22

(560)

XCH160-***

XPH160-***

 

 lnine chemical heat exchangers are ideal for one-pass cooling of chemicals dumping to waste stream. This product is also appropriate for heating applications. The system innovatively eliminates high costs associated with water aspiration. Utilizing PP or PVDF housing and fluoropolymer tubing, It is configured for your application with custom sizes available.


Service: In-line chemical heat exchanger with all fluoropolymer wetted surfaces (tubing side) for virtually any wet chemistry application.


Standard Sizes:

• 6.5 ft2 (.65m2) - 160ft2 (20m2) of exchange area

Custom exchange area available, max to 550 ft2 (51m2) exchange area

Standard Features:
• ½-inch (12mm) heavy wall PFA tubing, .030” (0.76mm) thick
• All welded construction (shell)
• 10-22 inch (255-560mm) diameter Polypropylene/PVDF shell
• Internally baffled for enhanced heat exchanger performance
• “U” factor (depending on flow rate): 25-50 BTU/(hr x ft2 x °F) = 142-284 J/(s x m2 x °C)
• Shell-side drain connection


Fluid Connections:
• Fluid (tube): ½-inch (12mm) male flare PFA/PTFE
• Shell: Flange connection according to customer request
• Shell drain: ¼-inch (6mm) male flare PFA/PTFE


Maximum Pressure/Temperature: 
• Tube (PFA): 35 PSIG (241 kPa) at 120ºC (250ºF)
• Shell (PP): 30 PSIG (206 kPa) at 82ºC (180ºF)
• Optional shell (PVDF): 30 PSIG (206 kPa) at 135ºC (275ºF)


Warranty: One year


Options:
• Custom sizes based on application
• PVDF shell

 

Custom exchange area and size are available



Copyright © 2013 Guangzhou Precise Heater Co.,LTD.All Rights Reserved 犀牛云提供企业云服务