Immersion Coils Heat Exchangers
PVDF/PFA/PTFE Heat Exchangers
PVDF/PFA/PTFE Heat Exchangers
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32551 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80)XC-40-3483.51 FNPT39.5(1000)35.5(900)3.15(80)XC-40-36891 FNPT39.5(1000)39.5(1000)3.15(80)XC-40-4094.51 FNPT39.5(1000)39.5(1000)3.15(80)XC-41-41991 FNPT43.3(1100)39.5(1000)3.15(80)XC-43-401041-1/2 FNPT43.3(1100)39.5(1000)3.54(90)XC-44-401101-1/2 FNPT45.3(1150)39.5(1000)3.54(90)XC-45-401151-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-47-401201-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-48-41Materials of ConstructionMaterials of construction for the Immersion Coil Heat Exchanger consists of either polypropylene, PVDF, or PTFE for the frame, and either FEP, PFA, or PTFE for the tubing. Custom designs may include other fluoropolymer materials such as ETFE, ECTFE or PCTFE.AdvantagesThe advantages of our heat exchanger products over alternative designs include:Low operating cost - The operating cost includes maintenance such as inspection, cleaning, downtime, and repair. This is primarily due to the relatively simple design that involves no plastic welding jointsNo weld joints - Unlike metals that are subject to more rapid degradation under aggressive pickle bath conditions, Fluorotherm’s heat exchangers withstand aggressivenessOff the shelf repair kits - In case of an unlikely event of accidental tube damage, these kits enable a quick repair of the tubingNo tube bundling - The strong tubing coils are optimally spaced so acid flow and therefore heat transfer is maintained without fouling.Constant operating efficiency - Fluoropolymers such as PTFE, FEP or PFA, are inherently  “non-stick”, so fouling by scale deposition is minimized, assuring a constant operating efficiency that does not decrease over time. No other material, except natural diamond, inhibits sticking of the pickle bath particulates more than fluoropolymers H2 TM Conductive Immersion Coil Heat Exchangers Manufactures H2 conductive tubing coil heat exchangers for use in restricted spaces in new and retrofit applications. This product provides between 2.3 to 2.7times the heat transfer capability of clear, natural tubing coils. The heat transfer rate is similar to steel without the corrosion attack susceptibility. It is also used in baths where electrical static discharge is a major concern. This product has undergone several iterations of improvement in properties and is unique to our line of heat exchanger offerings.  Custom exchange area and size are available
Inline Fluoropolymer Chemical Heat Exchangers
Inline Fluoropolymer Chemical Heat Exchangers
Inline Fluoropolymer Chemical Heat Exchangers:Fluoropolymer Inline Heat ExchangersExchange Area(Sq.Ft)LengthIn(mm)DIAIn(mm)PP ShellPVDF Shell6.515.7(400)10(255)XCH6.5-***XPH6.5-***1315.7(400)12(305)XCH13-***XPH13-***2020(500)14(355)XCH20-***XPH20-***3020(500)14(355)XCH30-***XPH30-***4024(600)14(355)XCH40-***XPH40-***5024(600)16(405)XCH50-***XPH50-***6027.5(700)16(405)XCH60-***XPH60-***7027.5(700)16(405)XCH70-***XPH70-***8031.4(800)16(405)XCH80-***XPH80-***9031.4(800)18(460)XCH90-***XPH90-***10031.4(900)18(460)XCH100-***XPH100-***11031.4(900)20(510)XCH110-***XPH110-***12039(1000)20(510)XCH120-***XPH120-***13039(1000)20(510)XCH130-***XPH130-***14043(1100)22(560)XCH140-***XPH140-***15043(1100)22(560)XCH150-***XPH150-***16047(1200)22(560)XCH160-***XPH160-***  lnine chemical heat exchangers are ideal for one-pass cooling of chemicals dumping to waste stream. This product is also appropriate for heating applications. The system innovatively eliminates high costs associated with water aspiration. Utilizing PP or PVDF housing and fluoropolymer tubing, It is configured for your application with custom sizes available.Service: In-line chemical heat exchanger with all fluoropolymer wetted surfaces (tubing side) for virtually any wet chemistry application.Standard Sizes: • 6.5 ft2 (.65m2) - 160ft2 (20m2) of exchange areaCustom exchange area available, max to 550 ft2 (51m2) exchange areaStandard Features:• ½-inch (12mm) heavy wall PFA tubing, .030” (0.76mm) thick• All welded construction (shell)• 10-22 inch (255-560mm) diameter Polypropylene/PVDF shell• Internally baffled for enhanced heat exchanger performance• “U” factor (depending on flow rate): 25-50 BTU/(hr x ft2 x °F) = 142-284 J/(s x m2 x °C)• Shell-side drain connectionFluid Connections:• Fluid (tube): ½-inch (12mm) male flare PFA/PTFE• Shell: Flange connection according to customer request• Shell drain: ¼-inch (6mm) male flare PFA/PTFEMaximum Pressure/Temperature: • Tube (PFA): 35 PSIG (241 kPa) at 120ºC (250ºF)• Shell (PP): 30 PSIG (206 kPa) at 82ºC (180ºF)• Optional shell (PVDF): 30 PSIG (206 kPa) at 135ºC (275ºF)Warranty: One yearOptions:• Custom sizes based on application• PVDF shell Custom exchange area and size are available
 Metal Heating and Cooling Grid Coils
Metal Heating and Cooling Grid Coils
Metal Heating and Cooling Grid CoilsDesigned for the high demands of corrosive chemical heatingor cooling DOUBLE C STYLE GRID COILS DCGExchange Area Squre Ft12-1/2” WIDTH Tubes Depth(In./mm)     Length(In./mm)    Model number6.582612.5/31814/35526DCG-148.82612.5/31818/45726DCG-18122612.5/31824/60926DCG-2415.62612.5/31830/76226DCG-30192612.5/31836/91426DCG-3625.82612.5/31848/1,21926DCG-48292612.5/31854/1,37126DCG-5434.92612.5/31864/1,62526DCG-6418-1/2” WIDTH Tubes  Depth(In./mm)   Length(In./mm)      Model number133818.5/47018/45738DCG-18183818.5/47024/60924DCG-24233818.5/47030/76224DCG-3027.93818.5/47036/91424DCG-36353818.5/47048/1,21924DCG-4842.93818.5/47054/1,37124DCG-54513818.5/47064/1,62524DCG-6459.53818.5/47074/1,87924DCG-7424-1/2” WIDTH Tubes  Depth(In./mm)   Length(In./mm)     Model number24.65224.5/62224/60952DRG-24315224.5/62230/76252DRG-30385224.5/62236/91452DRG-3651.85224.5/62248/1,21952DRG-4858.65224.5/62254/1,37152DRG-54705224.5/62264/1,62552DRG-64815224.5/62274/1,87952DRG-74DOUBLE C STYLE GRID COILS DCGExchange # DEPTH LENGTH MODEL Area Sq Ft Tubes In/mm In/mm STYLE30-1/2” WIDTH Tubes Depth(In./mm)                        Length(In./mm)        Model number38.86430.5/75530/76264DCG-30476430.5/75536/91464DCG-3663.96430.5/75548/1,21964DCG-48726430.5/75554/1,37164DCG-54866430.5/75564/1,62564DCG-641006430.5/75574/1,87964DCG-741146430.5/75584/2,13464DCG-8436-1/2” WIDTHTubesDepth(In./mm)                       Length(In./mm) Model number57.47836.5/92736/91478DCG-3677.87836.5/92748/1,21978DCG-48887836.5/92754/1,37178DCG-541057836.5/92764/1,62578DCG-641227836.5/92774/1,87978DCG-741397836.5/92784/2,13478DCG-8448-1/2” WIDTHTubesDepth(In./mm)                   Length(In./mm)Model number103.810448.5/108048/1,219104DCG-48117.410448.5/108054/1,371104DCG-5414010448.5/108064/1,625104DCG-64162.810448.5/108074/1,879104DCG-74185.510448.5/108084/2,134104DCG-84These unique C-shape tube grids require a substantially smaller footprint to adequately heat or cool a given exchange area. They can be used in salt water, alkaline solutions and plating rinse tanks.Rugged construction with heavy gauge material in 316 stainless steel, titanium, zirconium or mild steel allows for long uninterrupted life. Fluoropolymer coating is available for corrosion protection at solution interface.Precision inlet and outlet manifolds enable single point connections that reduce potential for leaks while simplifying installation. Always consult your chemical supplier for proper sheathing material compatibility.ENTIRE EXCHANGER IS ACTIVE EXCHANGE AREACOMPACT LOW PROFILE DESIGNHIGH 100 PSI PRESSURE RATING (Custom higher pressure ratings available.Consult factory for additional information).UNLIMITED SIZES AVAILABLE. (Standard 6.58 sq. ft. to 185.5 sq. ft. of exchange area).LEAK FREE DESIGN PROVIDES LONG LIFEMOUNTING HANGERS AVAILABLECUSTOM RISERS AVAILABLEHORIZONTAL OR VERTICAL DESIGNS AVAILABLE
PTFE Coil Heat Exchangers & Immersion Heat Exchangers
PTFE Coil Heat Exchangers & Immersion Heat Exchangers
PTFE Coil Heat Exchangers & Immersion Heat Exchangers:Teflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32551 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80)XC-40-3483.51 FNPT39.5(1000)35.5(900)3.15(80)XC-40-36891 FNPT39.5(1000)39.5(1000)3.15(80)XC-40-4094.51 FNPT39.5(1000)39.5(1000)3.15(80)XC-41-41991 FNPT43.3(1100)39.5(1000)3.15(80)XC-43-401041-1/2 FNPT43.3(1100)39.5(1000)3.54(90)XC-44-401101-1/2 FNPT45.3(1150)39.5(1000)3.54(90)XC-45-401151-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-47-401201-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-48-41We also deliver fluoroplastic heat exchangers. These heat exchangers are made of fluoroplastics such as PTFE, FEP an PFA. Fluoroplastics are fully resistant against corrosive liquids and have very good non-stick properties. This means there is no building up of pollution and it reduces fouling and scaling. Fluoroplastics are pure and contain no softeners or plasticisers and are therefore very suitable for handling ultra-high-pure (UHP) applications in the semi-conductor industry.All types of fluoroplastic heat exchanger units feature a proven unique honeycomb structure. The tubes are integrated in the pipe sheet which provides a lightweight compact bundle design. This ensures a leak free flow of the process liquids. Teflon heat exchangers are almost maintenance free and have a very long lifetime.Shell & tube heat exchangersShell and Tube heat exchangers are single pass, typically countercurrent flow units designed for heating, cooling and condensing applications. Units incorporate flexible fluoropolymer tube bundles joined together to form integral honeycomb tube sheets and are available with FEP or Q-Series tubing with PTFE lined heads. Standard shell construction is carbon steel. Other shell materials available on request. The heat exchangers are ASME coded and equipped with nozzles according to ANSI or DIN. For a better heat transfer performance the heat exchangers can be equipped with PFA/Graphite tubes (Q-series).CoilCoils are widely used in the metal finishing and chemical processing industries, and are especially suited to batch and continuous steel pickling applications. The inherent non-stick characteristics of Teflon® resist corrosion and fouling, extend heat exchanger service life, and improve value-in-use through savings in plant maintenance costs.Tube bundleTube bundle heat exchangers are used for heating and cooling of corrosive fluids in a wide range of processes and applications. The well-known non-stick characteristics of fluoropolymer resist corrosion and reduce fouling. Reactor Coils are designed for immersion directly into the process vessel, and are most efficient when agitated in the process solution. During agitation, the flexing action of the coils helps reduce fouling and dislodges deposits that may have formed. This and other unique design features make the Reactor Coil ideal for crystallizer applications.MinicoilsMinicoils heat exchangers fully made of fluoroplastics are suitable for small pickling baths. The inherently high electrical resistance also helps prevent short circuits and stray currents in plating baths.
PTFE(Fluoropolymer) Immersion Coils
PTFE(Fluoropolymer) Immersion Coils
PTFE (Fluoropolymer) Immersion CoilsTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32553/4 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80)XC-40-3483.51 FNPT39.5(1000)35.5(900)3.15(80)XC-40-36891 FNPT39.5(1000)39.5(1000)3.15(80)XC-40-4094.51 FNPT39.5(1000)39.5(1000)3.15(80)XC-41-41991-1/2 FNPT43.3(1100)39.5(1000)3.15(80)XC-43-401041-1/2 FNPT43.3(1100)39.5(1000)3.54(90)XC-44-401101-1/2 FNPT45.3(1150)39.5(1000)3.54(90)XC-45-401151-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-47-401201-1/2 FNPT47.2(1200)39.5(1000)3.54(90)XC-48-41Materials of ConstructionOur materials of construction for the Immersion Coil Heat Exchanger consists of either polypropylene, PVDF, or PTFE for the frame, and either FEP, PFA, or PTFE for the tubing. Custom designs may include other fluoropolymer materials such as ETFE, ECTFE or PCTFE.AdvantagesThe advantages of our heat exchanger products over alternative designs include:Low operating cost - The operating cost includes maintenance such as inspection, cleaning, downtime, and repair. This is primarily due to the relatively simple design that involves no plastic welding jointsNo weld joints - Unlike metals that are subject to more rapid degradation under aggressive pickle bath conditions, Fluorotherm™’s heat exchangers withstand aggressivenessOff the shelf repair kits - In case of an unlikely event of accidental tube damage, these kits enable a quick repair of the tubingNo tube bundling - The strong tubing coils are optimally spaced so acid flow and therefore heat transfer is maintained without fouling.Constant operating efficiency - Fluoropolymers such as PTFE, FEP or PFA, are inherently “non-stick”, so fouling by scale deposition is minimized, assuring a constant operating efficiency that does not decrease over time. No other material, except natural diamond, inhibits sticking of the pickle bath particulates more than fluoropolymersH2 TM Conductive Immersion Coil Heat ExchangersPrecise Heater™ manufactures H2 conductive tubing coil heat exchangers for use in restricted spaces in new and retrofit applications. This product provides between 2.3 to 2.7-times the heat transfer capability of clear, natural tubing coils. The heat transfer rate is similar to steel without the corrosion attack susceptibility. It is also used in baths where electrical static discharge is a major concern. This product has undergone several iterations of improvement in properties and is unique to Fluorotherm™’s line of heat exchanger offerings.Hybrid Heat ExchangersPrecise Heater's hybrid frame heat exchangers were made specially for ultrapure and aggressive chemical heating and cooling. This new product combines the best components and design geometry for efficient heat transfer. The design, evolved from decades of field experience, is driven by the need to inhibit particulate settling on, and fouling of heat transfer surfaces. These particles (sludge and precipitates) fall out from the chemical reactions that occur during metal treatment in mineral acids, in the form of oxides, sulfates, chlorides, phosphates and other materials.