Power Supplies- Rectifiers
Pulse Reverse power supplies, Cabinet models
Pulse Reverse power supplies, Cabinet models
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular waveforms)Permanent short circuit and open circuit proofMicroprocessor controlled regulationMains supply: standard 380 V - 460 V/3~ +/- 10 % / 50-60 HzOptional: 200 V - 240 V/3~ +/- 10 % / 50-60 HzMax. effective output power: see below matrix CoolingWater cooled (designed for the direct installation at the electroplatingtank)Ambient temperature 40°COver temperature protected DesignCompact stainless steel casing; protection grade IP54 DC/Pulse connection in back panel (tin copper bus bars) Typepe80CD122 / pe80CD124pe80CD202 / pe80CD204pe80CD322 /pe80CD324*pe80CD402 /pe80CD404*Forward current2 x 120 A / 4 x 120 A2 x 200 A / 4 x 200 A2 x 320 A / 4 x 320 A2 x 400 A / 4 x 400 AReverse pulse current2 x 360 A / 4 x 360 A2 x 600 A / 4 x 600 A2 x 960 A / 4 x 960 A2 x 1200 A / 4 x 1200 ACurrent ratio IF : IRfree adjustableEffective current / DC2 x 159 A / 4 x 159 A2 x 265 A / 4 x 265 A2 x 424 A / 4 x 424 A2 x 530 A / 4 x 530 AMinimum time reverse-pulse0,1 msec.Water coolingMax. water inlet temperature23 - 26°CMax. water outlet temperature40°CWater consumption approx.3 l/min (*3,6 l/min)Typepe80CD442pe80CD482pe80CD522pe80CD602Forward current2 x 440 A2 x 480 A2 x 520 A2 x 600 AReverse pulse current2 x 1320 A2 x 1440 A2 x 1560 A2 x 1800 ACurrent ratio IF : IRfree adjustableEffective current / DC2 x 583 A2 x 636 A2 x 689 A2 x 795 AMinimum time reverse-pulse0,1 msec.Water coolingMax. water inlet temperature23 - 26°CMax. water outlet temperature40°CWater consumption approx.3 l/min3,4 l/minTypepe80CD642pe80CD722pe80CD762pe80CD802Forward current2 x 640 A2 x 720 A2 x 760 A2 x 800 AReverse pulse current2 x 1920 A2 x 2160 A2 x 2280 A2 x 2400 ACurrent ratio IF : IRfree adjustableEffective current / DC2 x 848 A2 x 954 A2 x 1007 A2 x 1060 AMinimum time reverse-pulse0,1 msec.Water coolingMax. water inlet temperature23 - 26°CMax. water outlet temperature40°CWater consumption approx.3,7 l/min4,1 l/min4,4 l/min4,6 l/minOperation / programming(via external pe8005 control unit)Large illuminated 5,7“ graphic display5 x 4 keypad for easy handling and navigationClear and user friendly menu navigation via well structured pulldown menusEasy generation of complex waveforms with up to 16 individualsteps with 2 individual amplitudes (Ix1 and Ix2 as well as tx1 andtx2), that can be positive or negativeMMC/SD card reader for software update, import / export ofdevice configuration, set values and storing of bus-logging dataRS485 interface (optional: PROFIBUS or TCP/IP)Synchronization function2 programmable output relaysAh-totalizer, dosage counter, timerProgrammable START rampParameters individually adjustable even during operationDisplayClear display of actual valuesGraphic view of the set value shape, actual values shown inoscilloscope-mode with real time oscilloscope-functionStatus, warning and error indicationResolution0 up to +/- xx.xA for Ix1 and Ix2; resolution: 100mA0 up to 9 999.9mSec for tx1 and tx2; resolution: 0,1mSecCycles (repeatings per step): 1 - 99
POWER STATION DC Cabinet Rectifiers
POWER STATION DC Cabinet Rectifiers
POWER STATION DC Cabinet RectifiersDC POWER SUPPLY Output power:max. 110kWDC current:  max. 5000A (at 22V)DC voltage:  max. 1000V (at 100A) Typical applications:Chrome platingAnodizing/Aluminium colouring Barrel platingRack plating Water cooled DC power supply in switch mode technology,designed for the direct installation at the electroplating tank withminimal space requirement. Variable output rangethe output range can be individually multiplied Characteristic valuesLinearity inaccuracy:- for amperage - for voltage Ripple less than Efficiency typical 85 % Powerfactor cos φ 0,95Constant current and voltage controlSoft start functionOver temperature protection Pulse operation optional Mains supply: standard 3 x 400 V +/- 10 % / 50-60 Hz(other voltages on request) CoolingWater cooled / cooling water specificationAmbient temperature 40°C (other on request)Stainless steel cooling system, over temperature protected Cooling water connections are located in the plinth DesignCompact Rittal TS cabinet; protection grade: IP54Powder coated, RAL 7035Mains supply below in cabinetCooling water connection in the plinth, 1/2“ connectionsDC output bus bars:- Low voltage outputs in rear panel of the cabinet - High voltage outputs inside the cabinetWith mains power switch, fuses and sub distributor in a separatesupply cabinet - optional availableDimensions (W x H x D) 400 x 2200 x 600mm incl. plinth ValuesStandard sizes - DC output1 1other sizes on requestDC current5000 A4000 A3000 A100 ADC voltage4V5V6V8V10 V12 V15 V18 V20 V22 V24 V30 V1000VMains supply3 x 400V ACWeightapprox. 260 kgControlStandard: peRB-interfaceOptional: external control via analog signals, also with integratedisolation amplifierSignals: 0-10V0-1V4-20mA0-20mA (other on request) Control unit for the controlling ofDC power supplies ofDesigned for electroplating applicationsLarge 3-line LCD-display, keypads foreasy programing/selectionCurrent and voltage infinitely adjustableby UP / DOWN buttonsCurrent and voltage presetAmpere-hour counter (totalizer)Protection grade: IP54Ambient temperature max. 40°C Optional available functionsPreset counter, dosage counter *Ramp function (start / stop ramp)Timer function for ON / OFF *Voltage / current alarm *Operating hours counterChopper timer (pulse-capable rectifier type requested)Pole changer function (mechanical / electronic) *Programmable DC steps (14 individual steps) *Extern ON* Indication / alarm outputControl via: RS485, PROFIBUS, TCP/IP (other on request)
Water cooled DC power supply-Rectifiers
Water cooled DC power supply-Rectifiers
Water cooled DC power supply-RectifiersPOWER STATIONDC rectifiers, Cabinet modelsCooling: Water cooled'DC-rectifiers. Floor mounted cabinet with switch mode technology, water-cooled'Current10 000 APower200 000 WVoltage1 000 VOutput power:max. 200kWDC current:  10000A / 2x 5000A (at 20V) DC voltage:  max. 1000V (at 200A) Typical applications:Chrome plating Anodizing/Aluminium colouring Barrel plating Rack plating Water cooled DC power supply in switch mode technology,designed for the direct installation at the electroplating tankwith minimized flor space. Extendable power rangeThe power range can be extended by wiring the DC outputs of severalcabinets in parallel (sum current) or in serial (sum voltage) Characteristic valuesLinearity inaccuracy:- for amperage - for voltage Ripple less than Efficiency typical 90 %Powerfactor 0,95Constant current and voltage control (optional: power regulation) Inrush current protectionOver temperature protectionPulse operation optionalMains supply: standard 3 x 400 V +/- 10 % / 50-60 Hz(other voltages on request)Optional with integrated pole changer (max. 15V, other on request) CoolingWater cooled / cooling water specification:Ambient temperature 40°C (other on request)Stainless steel cooling systemover temperature protectedCooling water connections are located in the plinth DesignCompact Rittal TS cabinet; protection grade: IP54Powder coated, RAL 7035Mains supply below in cabinetCooling water connection in the plinth, 1/2“ connections(water pressure: 2-5 bar)DC output bus bars:- Low voltage outputs up to 50V on top of the cabinet - Voltages above 50V: touch safe designMains power switch, fuses and sub distributor optional available inseparate cabinet.Mouldes-case circuit breaker with short-circuit protection, low-voltagerelease and overload protection can be installed as option.Dimensions (W x H x D) 800 x 2200 x 600mm incl. plinth ValuesStandard sizes - DC output1 1other sizes on requestDC current10000 A5000 A2000 A200 ADC voltage10 V12 V15 V18 V20 V40 V100 V1000VMains supply3 x 400V ACWeightapprox. 450 - 550 kgControlStandard: peRB-interfaceOptional: external control via analog signals, also with integratedisolation amplifierSignals: 0-10V0-1V4-20mA0-20mA (other on request) Control unit for the controlling ofDC power supplies ofDesigned for electroplating applicationsLarge 3-line LCD-display, keypads foreasy programing/selectionCurrent and voltage infinitely adjustableby UP / DOWN buttonsCurrent and voltage presetAmpere-hour counter (totalizer)Protection grade: IP54Ambient temperature max. 40°C
 Air cooled DC rectifiers- DC POWER SUPPLY
Air cooled DC rectifiers- DC POWER SUPPLY
Air cooled DC rectifiers- Bench top models CoolingCurrent12 APower200 WVoltage100 VOutput power: max. 200 WattsDC current: max. 12A (at 15V) DC voltage: max. 30V (at 2A ) Typical applications:Laboratory plating lines Reel-to-reel plating Precious metal plating PCB linesManual plating lines Characteristic valuesLinearity inaccuracy Ripple less than Powerfactor cos φ 0,95Constant current and voltage control Soft start functionOver temperature protection Current and voltage presetProgrammable control unitLarge 3-line LCD displayKeypad for operation and programmingIntegrated Ampere-hour counter (totalizer)(preset counter and other functions optional available) Mains supply: standard 230 V +/- 10 % / 50-60 Hz (other voltages on request) CoolingOptimized cooling air guiding, air consumption max. 50m3/hCooling air outlet at the device back panelAmbient temperature 35°C (other on request) DesignCompact desktop unit, protection grade IP21Casing powder coated colour RAL 9018 (Standard)Aluminium front panel with polycarbonat filmDC connection in front or back panel (lead through bolts oroval flat clamp)Easy installation ValuesStandard sizes - DC output1 1other sizes on requestDC current12 A10 A8A6A2ADC voltage4V5V6V8V10 V12 V15 V18 V20 V24 V30 V100 VMains supply230 V ACWeightapprox. 8 kgControl optional availableAnalog signals galvanically isolated via isolation amplifier:0-10V, 4-20mA, 0-20mA (other on request), X4-terminal Serial interface RS485: X6 and X7 terminal Optional available functionsPreset counter, dosage counter * Ramp function (start / stop ramp) Timer function for ON / OFF * Voltage / current alarm * Operating hours counterChopper timerPole changer function (mechanical / electronic) * Programmable DC steps (14 individual steps) *Extern ON / External enabling* Indication / alarm outputOptional availableSeparate electronic controlled pole changerDC connectorcan be installed in front or back panel
Pulse Reverse power supplies
Pulse Reverse power supplies
Pulse Reverse power suppliesPulse Reverse power supplies, Bench top modelsCooling: Air cooledOutput power: max. 6360 WattsEffective - and DC-current: max. 318 APulse current: max. 720 AEffective voltage: max. 500 VOutput power:  max. 6360 WattsEffective - and DC-current:  max. 318 AReverse-current: max. 720 AEffective voltage: max. 500 VTypical applications:PCB lines Pulse plating Reel-to-reel plating Characteristic valuesSwitch mode technologySingle or Dual output availableLinearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular waveforms)Permanent short circuit and open circuit proofMicroprocessor controlled regulationMains supply: standard 3x380 V - 460 V +/- 10 % / 50-60 Hz(other voltage on request)Max. effective output power: 1x 6360 Watts or 2x 3180 Watts CoolingAir cooled, air consumption max. 510m3/hAmbient temperature 35°C (other on request)Over temperature protectedDesignCompact 19“ unit; protection grade IP21Stainless steel casingAluminium front panelDC/Pulse connection in back panel (high voltage clamps) Dimensions (W x H x D): 483 x 179 x 520 mm For ExampleTypeDA-6-159-360-Dother sizes on requestEffective current / DC2 x 159 AForward pulse2 x 360 AReverse pulse2 x 360 AEffective voltage2x 6 VMains supply3 x 400 V ACCoolingair cooled via three fansCooling air consumption510 m3/hDimensions483 x 178 x 620(W x H x D)Weightapprox. 45 kgOperation / programming (via external pe8005 control unit)Large illuminated 5,7“ graphic display5 x 4 keypad for easy handling and navigationClear and user friendly menu navigation via well structured pull downmenusEasy generation of complex waveforms with up to 16 individual stepswith 2 individual amplitudes (Ix1 and Ix2 as well as tx1 and tx2), thatcan be positive or negativeMMC/SD card reader for software update, import / export of deviceconfiguration, set values and storing of bus-logging dataSynchronization function2 programmable output relaysAh-totalizer, dosage counter, timerProgrammable START rampParameters individually adjustable even during operationDisplayClear display of actual valuesGraphic view of the set value shape, actual values shown in oscilloscope-modeStatus, warning and error indicationResolution0 up to +/- xx.xA for Ix1 and Ix2; resolution: 100mA0 up to 9 999.9mSec for tx1 and tx2; resolution: 0,1mSecCycles (repeatings per step): 1 - 99
Copyright © 2013 Guangzhou Precise Heater Co.,LTD.All Rights Reserved 犀牛云提供企业云服务